For the complete documentation index, see llms.txt. This page is also available as Markdown.

DC686 Controls - LED's & OSD

The DC686 has five white buttons (K1–K5) and one red power button. Use them to change fusion modes, adjust the keying strength, and view device information.

1. Button shortcuts

The five white buttons are numbered K1 through K5 from left to right.

Button
Short press
Long press

K1

Show device parameters in the top-left corner of the monitor.

Hold 5 seconds: switch between AUTO EDID and injected EDID mode.

K2

Increase the keying strength (ALPHA).

Hold 5 seconds: change the monitor ID, serial number, and related identification information. The fuser restarts automatically; the power light flashes quickly five times.

K3

Decrease the keying strength (ALPHA).

Hold 3 seconds: reserved; no current function specified.

K4

Cycle through the fusion modes.

Hold 5 seconds: restore factory settings, native monitor EDID, ALPHA = 20, capture source DP0, and clear injected parameters. The power light flashes quickly five times after success.

K5

Switch to displaying only the main PC or only the secondary PC; fusion/keying is disabled in single-input display mode.

Hold 3 seconds: reserved; no current function specified.

Red power button

Pressed inward: power on. Released outward: power off.

—

ALPHA / keying strength

  • Adjustable range: 5–255.

  • Manufacturer default: 20.

  • If using the YCbCr 4:2:2 color format, the manual instructs you to set the keying strength to 20.

  • Use K2 to increase and K3 to decrease this value.

Note: The manufacturer calls this setting keying strength (抠图强度). The manual does not define the exact visual behavior of each fusion mode.

2. View the OSD information

Short-press K1 to display the device's on-screen display (OSD) parameters in the upper-left corner.

OSD label
Meaning

DP0

Main PC resolution and refresh rate. A Y indicates that this input is being displayed by itself.

DP1

Secondary PC resolution and refresh rate. A Y indicates that this input is being displayed by itself.

EDID

AUTO = automatically adapt to the monitor (default). EDID = injected EDID mode.

ALPHA

Current keying strength, adjustable from 5 to 255; default 20.

RH

Fusion status: ON = enabled; OFF = disabled.

CJ

Capture mode: DP0 = capture only the main PC's image; DP1 = capture the combined two-layer image.

SN

Current monitor serial number.

ID

Current monitor ID.

FW

Firmware date.

TEMP

Current device temperature.

DNA

Unique device chip identifier.

3. Switch EDID modes or reset settings

To switch between normal automatic EDID handling and an injected EDID, hold K1 for 5 seconds. The OSD will show either AUTO or EDID.

To return to the manufacturer's defaults, hold K4 for 5 seconds. This restores the monitor's native EDID information, sets ALPHA to 20, sets capture to DP0, and clears injected parameters.

Warning: A factory reset removes any injected EDID configuration. If you need a custom EDID, keep a copy of the file so you can inject it again.

Next steps

  • Setup & Connections

  • Firmware Updates & EDID

  • High Refresh Rates & Troubleshooting

Last updated