DC686 Firmware & EDID

The Dichen Technology Serial Port Management Tool is used to update the DC686's firmware and inject an EDID file. Both functions use the Data USB-C port on the fuser — not the Capture USB-C port.

1. Download the management utility

The manufacturer's manual provides this download location:

Download the Dichen utilities Archive/access password: 6666

Note: This is the manufacturer-provided external download, reproduced from the October 15, 2026 manual. The interface shown in the screenshots is in Chinese; the button names below are translated into English.

2. Update the firmware

  1. Connect a computer to the DC686's Data USB-C port.

  2. Open the Dichen Technology Serial Port Management Tool (帝辰科技串口管理工具).

  3. Allow the utility to detect the fuser and check for the latest firmware automatically. Alternatively, click Check Firmware (检查固件).

  4. Select the newest available firmware.

  5. Click Download and Upgrade (下载并升级).

  6. Allow the update to complete. The manual states that the process should finish within approximately four minutes, after which the fuser restarts automatically.

Expected behavior: If the device is in use during the update, the display will go black temporarily. This is described as normal behavior in the manufacturer manual.

Firmware utility translation

Original Chinese
English

固件升级

Firmware Upgrade

检查固件

Check Firmware

下载并升级

Download and Upgrade

刷新串口

Refresh Serial Ports

连接设备

Connect Device

EDID 管理

EDID Management

3. Inject a custom EDID file

Use this when you need to load a particular EDID profile into the fuser.

  1. Connect the computer to the DC686's Data USB-C port.

  2. Open the Dichen Technology Serial Port Management Tool.

  3. Open the EDID Management (EDID 管理) tab.

  4. Click Select File (选择文件), then choose the EDID file you want to use.

  5. Click Inject EDID (注入 EDID) to write it to the device.

  6. To use an injected EDID profile, switch to EDID mode by holding K1 for 5 seconds until the OSD shows EDID instead of AUTO.

What to expect during EDID injection

  • If the fuser is currently operating in EDID injection mode, the display may turn black for a few seconds during the injection.

  • If the fuser is in its default AUTO mode, the manual states that injecting the file does not cause a black screen.

  • AUTO is the default automatic mode; EDID is injected-EDID mode.

EDID utility translation

Original Chinese
English

选择文件

Select File

注入 EDID

Inject EDID

启用 EDID

Enable EDID

切回 AUTO

Switch Back to AUTO

EDID 管理

EDID Management

4. Restore the original monitor information

Hold K4 for 5 seconds to perform a factory reset. As described by the manufacturer, this:

  • Restores the monitor's native EDID information.

  • Resets ALPHA to 20.

  • Sets the capture source to DP0.

  • Clears the injected parameters.

  • Causes the power indicator to flash quickly five times when complete.

For a detailed explanation of the physical buttons, see Button Controls & On-Screen Display.

Next steps

  • Setup & Connections

  • Button Controls & On-Screen Display

  • High Refresh Rates & Troubleshooting