DC686 Firmware & EDID
The Dichen Technology Serial Port Management Tool is used to update the DC686's firmware and inject an EDID file. Both functions use the Data USB-C port on the fuser — not the Capture USB-C port.
1. Download the management utility
The manufacturer's manual provides this download location:
Download the Dichen utilities
Archive/access password: 6666
Note: This is the manufacturer-provided external download, reproduced from the October 15, 2026 manual. The interface shown in the screenshots is in Chinese; the button names below are translated into English.
2. Update the firmware
Connect a computer to the DC686's Data USB-C port.
Open the Dichen Technology Serial Port Management Tool (帝辰科技串口管理工具).
Allow the utility to detect the fuser and check for the latest firmware automatically. Alternatively, click Check Firmware (检查固件).
Select the newest available firmware.
Click Download and Upgrade (下载并升级).
Allow the update to complete. The manual states that the process should finish within approximately four minutes, after which the fuser restarts automatically.
Expected behavior: If the device is in use during the update, the display will go black temporarily. This is described as normal behavior in the manufacturer manual.
Firmware utility translation
固件升级
Firmware Upgrade
检查固件
Check Firmware
下载并升级
Download and Upgrade
刷新串口
Refresh Serial Ports
连接设备
Connect Device
EDID 管理
EDID Management
3. Inject a custom EDID file
Use this when you need to load a particular EDID profile into the fuser.
Connect the computer to the DC686's Data USB-C port.
Open the Dichen Technology Serial Port Management Tool.
Open the EDID Management (EDID 管理) tab.
Click Select File (选择文件), then choose the EDID file you want to use.
Click Inject EDID (注入 EDID) to write it to the device.
To use an injected EDID profile, switch to EDID mode by holding K1 for 5 seconds until the OSD shows
EDIDinstead ofAUTO.
What to expect during EDID injection
If the fuser is currently operating in EDID injection mode, the display may turn black for a few seconds during the injection.
If the fuser is in its default AUTO mode, the manual states that injecting the file does not cause a black screen.
AUTO is the default automatic mode; EDID is injected-EDID mode.
EDID utility translation
选择文件
Select File
注入 EDID
Inject EDID
启用 EDID
Enable EDID
切回 AUTO
Switch Back to AUTO
EDID 管理
EDID Management
4. Restore the original monitor information
Hold K4 for 5 seconds to perform a factory reset. As described by the manufacturer, this:
Restores the monitor's native EDID information.
Resets ALPHA to 20.
Sets the capture source to DP0.
Clears the injected parameters.
Causes the power indicator to flash quickly five times when complete.
For a detailed explanation of the physical buttons, see Button Controls & On-Screen Display.
Next steps
Setup & Connections
Button Controls & On-Screen Display
High Refresh Rates & Troubleshooting